Compatibility with Pittsburgh MIDI

Home Forums Support Compatibility with Pittsburgh MIDI

This topic contains 5 replies, has 2 voices, and was last updated by Avatar of Christian Christian 9 years, 11 months ago.

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #1045
    Avatar of B
    B
    Participant

    I don’t know why, but the ZAQuencer can’t seem to send expected MIDI to my Pittsburgh Modular MIDI module (old version). I have checked that it sends fine and correct to MIDI in on my computer, and I have checked that I can send a MIDI sequence from the computer to the Pittsburgh module correctly (via Nodal; this works just fine), but when I send a note-pitch-randomized 32-step sequence from the ZAQuencer to the Pittsburgh, I generally get just a drone of a single note that may change occasionally. On the software end, MIDI Monitor shows that the ZAQuencer is sending note on at 127 velocity followed by note off at 0 on channel 1, which looks right to me.

    I’ve tried setting the ZAQuencer to all of 16 MIDI channels, both the A and B physical outs (with A, B, and AB out settings for the sequence). I’ve tried recording a MIDI sequence in Logic and replaying it to the Pittsburgh — this has exactly the same effect as sending directly, so I don’t think it’s a purely electrical issue, but instead, a disagreement about the MIDI data.

    Do you have any idea what might be going on here?

    #1063
    Avatar of Christian
    Christian
    Keymaster

    Hm… I´ve been trying to think what could be happening here.

    Two things sprung to mind:
    - have you experimented with the note length parameter in the Zaquencer yet?
    maybe the notes are set too long?
    - there are two ways of ending a midi note, sending Note Off, or sending Note On with velocity 0 (like we do). Maybe the Pittsburgh doesn´t like it that way?

    #1090
    Avatar of B
    B
    Participant

    I’ve set the note length short, so I don’t think that’s it. Here are a couple short captures from MIDI Monitor, with the unnecessary bits omitted:

    Sequence sent from Logic, recognized OK on the Pittsburgh:
    *** ZERO *** Note On 1 C3 80
    *** ZERO *** Note Off 1 C3 64
    *** ZERO *** Note On 1 C#3 80
    *** ZERO *** Note Off 1 C#3 64
    *** ZERO *** Note On 1 F3 80
    *** ZERO *** Note Off 1 F3 64
    *** ZERO *** Note On 1 C2 80
    *** ZERO *** Note Off 1 C2 64

    Sequence sent from ZAQuencer, malfunctioning:
    15:27:28.205 Note On 1 C3 127
    15:27:28.248 Note Off 1 C3 0
    15:27:28.580 Note On 1 C#3 127
    15:27:28.623 Note Off 1 C#3 0
    15:27:28.955 Note On 1 F3 127
    15:27:28.998 Note Off 1 F3 0
    15:27:29.330 Note On 1 C2 127
    15:27:29.372 Note Off 1 C2 0

    Anything stand out to you?

    #1094
    Avatar of Christian
    Christian
    Keymaster

    Email sent

    #1231
    Avatar of Christian
    Christian
    Keymaster

    For anyone following this, the problem went away when we switched to sending NoteOff from the Zaquencer. This will be incorporated in a future update.

    • This reply was modified 10 years ago by Avatar of Christian Christian.
    #1661
    Avatar of Christian
    Christian
    Keymaster

    Fixed in 1.01

Viewing 6 posts - 1 through 6 (of 6 total)